SLA Batteries

Rechargeable sealed lead-acid batteries

  • Operation: -20 to +60 degrees
  • Typical battery life: 5 years

12 volt, 7.2 amp-hour

This battery is recommended for the OWL when 12 volts is required by external equipment such as the Irrometer, tensiometer, or Anabat. The OWL itself can operate on either 6 or 12 volts.

  • 6 x 2.5 x 4 inches
  • 5.4 lbs
  • connections via 3/16 inch fast-on tabs, spaced 2 inches apart.
  • charging at 25 degrees Celsius:
    • float charge at 13.8 volts at 20 degrees Celsius. Temperature compensate (-0.025 volts per deg. C), i.e. 13.3 volts at 40 deg. C, 14.3 volts at 0 deg. C.
    • cycle fast charge at 14.6 volts, <0.5 amps. Temperature compensate (-0.025 volts per deg. C), i.e., 14.1 volts at 40 deg. C 15.1 volts at 0 deg. C. Switch to float when I<40 milliamps.
CHARGING INSTRUCTIONS (At 5°C-35°C)(AT 41°F-95°F)
ApplicationVoltageCurrent
Standby13.5-13.80.3 Capacity
Cycle Use14.4-15.00.3 Capacity
    • The CG1129 battery charger is suitable for charging this battery from a solar panel.

6 volt, 12 amp-hour

This battery is recommended for the OWL when 6 volts can operate everything in the system. The OWL itself can operate on either 6 or 12 volts.

  • 6 x 2 x 4 inches
  • 4.2 lbs
  • connections via 3/16 inch fast-on tabs, spaced 4.5 inches apart.
  • charging at 25 degrees Celsius:
    • float charge at 13.8 volts at 20 degrees Celsius. Temperature compensate (-0.025 volts per deg. C), i.e. 13.3 volts at 40 deg. C, 14.3 volts at 0 deg. C.
    • cycle fast charge at 14.6 volts, <0.7 amps. Temperature compensate (-0.025 volts per deg. C), i.e., 14.1 volts at 40 deg. C 15.1 volts at 0 deg. C. Switch to float when I<60 milliamps.
CHARGING INSTRUCTIONS (At 5°C-35°C)(AT 41°F-95°F)
ApplicationVoltageCurrent
Standby6.75-6.900.3 Capacity
Cycle Use7.20-7.500.3 Capacity
    • The CG1129 battery charger is suitable for charging this battery from a solar panel.